Agent skill
hvac-design
Skill for HVAC system design and analysis per ASHRAE standards including load calculations, equipment selection, and energy efficiency analysis
Install this agent skill to your Project
npx add-skill https://github.com/a5c-ai/babysitter/tree/main/library/specializations/domains/science/mechanical-engineering/skills/hvac-design
Metadata
Additional technical details for this skill
- phase
- 6
- domain
- science
- category
- thermal-fluid-analysis
- priority
- high
- specialization
- mechanical-engineering
- tools libraries
-
[ "Carrier HAP", "Trane TRACE", "EnergyPlus", "eQUEST" ]
SKILL.md
HVAC System Design Skill
Purpose
The HVAC System Design skill provides comprehensive capabilities for heating, ventilation, and air conditioning system design according to ASHRAE standards, enabling systematic load calculations, equipment selection, ductwork design, and energy efficiency analysis for commercial and industrial buildings.
Capabilities
- Heating and cooling load calculations
- Psychrometric analysis and chart calculations
- Equipment selection (AHU, chillers, boilers)
- Duct and piping system sizing
- Energy efficiency analysis (ASHRAE 90.1)
- Indoor air quality assessment (ASHRAE 62.1)
- System simulation and optimization
- Control system specification
Usage Guidelines
Load Calculations
Cooling Load Components
-
External Loads
- Solar radiation through windows (SHGC consideration)
- Conduction through envelope (walls, roof, floor)
- Infiltration and ventilation air
-
Internal Loads
- People: 250 Btu/h sensible, 200 Btu/h latent (typical office)
- Lighting: Use installed wattage with diversity
- Equipment: Plug loads with usage factors
-
Calculation Methods
- CLTD/CLF method: Manual calculations
- RTS (Radiant Time Series): More accurate
- Heat Balance Method: Full simulation
Heating Load
-
Design Conditions
- Use ASHRAE 99.6% or 99% design temperature
- No solar credit for heating design
- Full infiltration at design conditions
-
Load Components
- Envelope conduction (U × A × ΔT)
- Infiltration/ventilation (1.08 × CFM × ΔT)
- No internal gains credited
Psychrometric Analysis
-
Key Properties
- Dry-bulb and wet-bulb temperatures
- Relative humidity and humidity ratio
- Enthalpy and specific volume
- Dew point temperature
-
Process Calculations
Process Constant Property Sensible heating/cooling Humidity ratio Humidification Enthalpy (adiabatic) Dehumidification Saturation curve Mixing Mass-weighted average -
Coil Processes
Sensible Heat Ratio (SHR) = Qs / Qt Bypass Factor (BF) = (T_leaving - T_ADP) / (T_entering - T_ADP)
Equipment Selection
Air Handling Units
-
Coil Sizing
- Entering/leaving air conditions
- Water temperatures (chilled water: 44/54°F typical)
- Face velocity: 400-550 fpm
-
Fan Selection
- Total static pressure requirements
- Fan efficiency and motor sizing
- Variable speed considerations
Chillers
-
Types and Selection
- Reciprocating: < 200 tons
- Scroll: 20-400 tons
- Screw: 100-1500 tons
- Centrifugal: > 300 tons
-
Efficiency Metrics
- COP (Coefficient of Performance)
- kW/ton: 0.5-0.8 typical range
- IPLV: Part-load efficiency
Duct Design
-
Sizing Methods
- Equal friction: Constant pressure drop per 100 ft
- Static regain: Constant velocity pressure
- Velocity method: Noise-controlled
-
Pressure Drop
- Typical systems: 0.08-0.1 in.w.g./100 ft
- Low velocity: < 0.08 in.w.g./100 ft
- High velocity: > 0.1 in.w.g./100 ft
-
Fitting Losses
- Express as equivalent length or C coefficient
- Use ASHRAE duct fitting database
Energy Efficiency
-
ASHRAE 90.1 Compliance
- Envelope requirements (U-values, SHGC)
- HVAC efficiency minimums
- Lighting power density limits
- Energy cost budget method
-
Energy Conservation Measures
- Economizer operation
- Heat recovery
- Variable speed drives
- Demand-controlled ventilation
Process Integration
- ME-013: HVAC System Design
Input Schema
{
"building": {
"location": "string",
"type": "office|retail|healthcare|industrial",
"gross_area": "number (ft2)",
"floors": "number"
},
"design_criteria": {
"indoor_summer": {
"temp": "number (F)",
"rh": "number (%)"
},
"indoor_winter": {
"temp": "number (F)"
},
"ventilation_standard": "ASHRAE 62.1|local code"
},
"internal_loads": {
"occupancy": "number (people)",
"lighting": "number (W/ft2)",
"equipment": "number (W/ft2)"
}
}
Output Schema
{
"loads": {
"peak_cooling": "number (tons)",
"peak_heating": "number (MBH)",
"ventilation": "number (CFM)"
},
"equipment": {
"ahu": [{
"designation": "string",
"supply_cfm": "number",
"cooling_tons": "number",
"heating_mbh": "number"
}],
"chiller": {
"type": "string",
"capacity": "number (tons)",
"efficiency": "number (kW/ton)"
},
"boiler": {
"type": "string",
"capacity": "number (MBH)",
"efficiency": "number (%)"
}
},
"energy_analysis": {
"annual_cooling": "number (kWh)",
"annual_heating": "number (therms)",
"eui": "number (kBtu/ft2/yr)"
}
}
Best Practices
- Use ASHRAE weather data for design conditions
- Apply appropriate safety factors (10-15% typical)
- Consider zone diversity for central equipment
- Verify ventilation rates meet ASHRAE 62.1
- Model energy performance before finalizing design
- Coordinate with architectural and structural disciplines
Integration Points
- Connects with CFD Analysis for airflow modeling
- Feeds into Thermal Analysis for component design
- Supports Building Energy Simulation for annual performance
- Integrates with Control System Design for automation
Recommended Agent Skills
Expand your agent's capabilities with these related and highly-rated skills.
gsd-tools
Central utility skill for GSD operations. Provides config parsing, slug generation, timestamps, path operations, and orchestrates calls to other specialized skills. Acts as the unified entry point that the original gsd-tools.cjs provided via its lib/ modules (commands, config, core, init).
model-profile-resolution
Resolve model profile (quality/balanced/budget) at orchestration start and map agents to specific models. Enables cost/quality tradeoffs by selecting appropriate AI models for each agent role.
verification-suite
Plan structure validation, phase completeness checks, reference integrity verification, and artifact existence confirmation. Provides the structured verification layer ensuring GSD artifacts are well-formed and complete.
state-management
STATE.md reading, writing, and field-level updates. Provides cross-session state persistence via .planning/STATE.md with structured fields for current task, completed phases, blockers, decisions, and quick tasks.
git-integration
Git commit patterns, formats, and conventions for GSD methodology. Provides atomic commits per task, structured commit messages, planning file commits, branch management, and milestone tag operations.
frontmatter-parsing
YAML frontmatter parsing and manipulation for .planning/ documents. Provides read, write, update, query, and validation operations on frontmatter blocks in GSD markdown artifacts.
Didn't find tool you were looking for?